Inquiry
Form loading...
Products Categories
Featured Products
01

CO (Carbon Monoxide) Detector LX-201

2021-07-22 19:13:57
Technical Parameters 1. Power supply: 9VDC 2. Static current: <35μA 3. Alarm current: <20mA 4. Alarm sonority: ≥85dB 5. Alarm density: 150±50PPM 6. Working temperature: 4℃--38℃ 7. Working humidity: 25%--85%RH 8. Static indication: red LED light flash 1 time / second 9. Low voltage alarm: a sharp sound / 30 second 10. Product size: 10.2x10.2 x3.7cm Packing Data
view detail
01

CO (Carbon Monoxide) Detector LX-203

2021-07-22 19:13:55
Carbon Monoxide Detector Model #: LX-203 Technical Parameters 1. Power supply: 220VAC 2. Power consumption: 3.8W 3. Alarm sonority: ≥85dB 4. Working temperature: 4℃--38℃ 5. Working humidity: 25%--85%RH 6. Low voltage alarm: a sharp sound / 15s 7. Static indication: red LED light flash 1 time/ 2s 8. Can be connected with system 9. At 70PPM, alarm within 60--240 minutes At 150PPM, alarm within 10-50 minutes At 400PPM, alarm within 4-15 minutes 10. Product size: 12.6x7.2 x4.6cm Packing Data Parts Description
view detail
01

CO (Carbon Monoxide) Detector LX-204

2021-07-22 19:13:55
Carbon Monoxide Detector Model #: LX-204 Technical Parameters 1. Power supply: 9VDC 2. Static current: <35μA 3. Alarm current: <20mA 4. Alarm sonority: ≥85dB 5. Working temperature: 4℃--38℃ 6. Working humidity: 25%--85%RH 7. Low voltage alarm: a sharp sound / 15s 8. Static indication: red LED light flash 1 time/ 2s 9. Product size: 10.9x10.9 x4.5cm Packing Data QTY/CTN CARTON SIZE QTY/20GP 100pcs 57x26.5x46.5CM 28800pcs Parts Description      
view detail
01

Gas Detector LX-211/211L

2021-07-22 19:13:51
Gas Detector Model #: LX-211 / 211L Technical Parameters 1. Power supply: 12VDC 2. Power consumption: 1.7W 3. Alarm sonority: ≥85dB 4. Sensitivity: 10% LEL 5. Working temperature: -10℃--+50℃ 6. Working humidity: <95%RH 7. LX-211L has relay, can connect to the system 8. Product size: 10.7x10.7 x3.6cm Packing Data QTY/CTN CARTON SIZE QTY/20GP 100pcs 43x23x55CM 49600pcs Parts Description      
view detail
01

Conventional gas detector LX-213L

2021-04-29 11:31:43
Non-Addressable gas detector,applicable to 4 wire non-addressable fire detection control and indicating equipment, it will alarm through light /sound when the combustible gas leaks. *Working voltage:16VDC~32VDC *Power consumption: 1.7W *Sensitivity : 10%LEL *Alarm sonority:≥85bd   *Working humidity: ≤95%RH *Operating temperature:-10℃ to +50℃ * Built-in signal relay *Regular packing is each gas detector is packed into a neutral white box, 100pcs/master carton  Status indication : When green light flash, sensor warm-up ; When green light on, sensor turn into the working status ; When red light flash, buzzer tweet by pulse, means it detects the combustible gas,and alarm through light/sound.  Practice fire safety: Expose everyone to the sound of the fire alarm in daily life and explain what the sound means and how to operate the fire alarm button if a fire occurs.Discuss in advance two exits from each room and an escape route to the outside from each exit.Teach them to crawl along the floor to stay below dangerous smoke,fumes and gases.Determine a safe meeting place in advance for all members outside the building. 3145852
view detail
01

Coal gas detector for home LX-212AD

2021-07-05 08:21:52
Model LX-212AD gas detector has superior gas sensor with Japan technology.Double power supply 220V AC or 12V DC optional. It has sensitivity of 10% LEL. This gas leak detector suitable for detecting LPG(Butane, Propane)used in normal and mini gas bottles,detecting gas from piping system (city gas) and natural gas (Methane).  Green indicator is for power.Red light is alarm indication.   Besides visual alarm signal of red indicator, the gas detector provides audible signal of 85db alarm sound,reducing the risk of gas explosion and protect your family’s life and property safety. Gas detectors are widely used at home,restaurant,hospital,garage or oil factory.
view detail
01

Natural gas detector for home LX-212ADL

2021-04-29 11:26:45
Model LX-212ADL gas detector has superior gas sensor with Japan technology.Double power supply 220V AC or 12V DC optional. It has sensitivity of 10% LEL. This gas leak detector suitable for detecting LPG(Butane, Propane)used in normal and mini gas bottles,detecting gas from piping system (city gas) and natural gas (Methane).   Green indicator is for power.Red light is alarm indication. The gas detector has built-in relay and can be connected to system solenoid valve and fan.   Besides visual alarm signal of red indicator, the gas detector provides audible signal of 85db alarm sound,reducing the risk of gas explosion and protect your family’s life and property safety. Gas detectors are widely used at home,restaurant,hospital,garage or oil factory.
view detail
01

Gas Detector LX-212ADS

2021-07-22 19:13:52
Gas Detector Model #: LX-212AS Technical Parameters 1. Power supply: 220VAC 2. Power consumption: 1.7W 3. Alarm sonority: ≥85dB 4. Sensitivity: 10% LEL 5. Working temperature: -10℃--+50℃ 6. Working humidity: ≤95%RH 7. Type of gas sensed: a) + LPG (Butane, Propane) used in normaland mini gas bottles b) + Gas from piping system (city gas) and natural gas(Methane) 8. Can be equipped with solenoid valve 9. Product size: 11.5x7.2 x4.4cm Packing Data QTY/CTN CARTON SIZE QTY/20GP 50pcs 55x25x28.5CM 35200pcs Parts Description  
view detail
01

CO And Gas Detector LX-214

2021-07-22 19:13:53
Technical Parameters 1. Power supply: 110VAC 2. Power consumption: 3.8W 3. Alarm sonority: ≥85dB 4. Sensitivity: 10% LEL 5. Working temperature: 4℃--38℃ 6. Working humidity: 25%--85%RH 7. Low voltage alarm: a sharp sound / 15s 8. Static indication: red LED light flash 1 time / 2s 9. CO sensitivity: a) at 70PPM, alarm within 60--240minutes b) at 150PPM, alarm within 10-50minutes c) at 400PPM, alarm within 4-15minutes 10. Product size: 15.5x9.7 x4.6cm Packing Data
view detail
01

Gas Detector LX-215

2021-07-22 19:13:54
Technical Parameters 1. Power supply: 220V / 110VAC 2. Power consumption: 1.7W 3. Alarm sonority: ≥85dB 4. Sensitivity: 10% LEL 5. Working temperature: -10℃--+50℃ 6. Working humidity: ≤ 95%R 7. Product size: 12.6x7.2 x4.6cm Packing Data
view detail
01

CO (Carbon Monoxide) Detector LX-202L

2021-07-22 19:13:56
Technical Parameters 1. Power supply: 24VDC 2. Static current: ≤7mA 3. Alarm current: ≤9mA 4. Alarm density: 400PPM 5. Working temperature: -10℃--+50℃ 6. Working humidity: 5%--95%RH 7. Can be connected with system 8. Product size: 10.9x10.9 x5.2cm Packing Data
view detail