Hand actuated alarm button connecting with fire alarm sys...
This fire alarm button is connected with main controller.When the button is activated by hand in the event of a fire, fire alarm bell connected with main controller will sound an alarm.
*Voltage:12V-50V DC
* Operating current: 3A
* Working temp: -10℃-+65℃
*Working humidity: 10﹪-90﹪RH
*Using method:Break the panel glass immediately once finding a fire
Security:with the emergency alarm button,you can bring enough safety to you and your family in the event of an emergency,and also inform firefighters to rescue timely.
Fire pull station LX-M3001
This pull station is is a manual alarm swtich which connects with fire alarm system.When pulling down the T handle in the event of a fire, fire alarm bell connecting with system will sound an alarm.
*Signal power:10Amps@120VAC
* Main material:Die-casting alloy panel+thicker steel plate+electronic components,electrostatic coating surface,base plate color zinc plating
*Color: Red+ white
* T-type operating handle,including tip glass rod
*Metal transmission structure, three-dimensional signs
*Single action and double action are available
*Application: This fire alarm pull station is suitable to be used in buildings, workshops and warehouses
Conventional fire alarm bell 6 inch size LX-907-6''AC/DC
This fire alarm bell can be connected with main controller.When the main controller receives signal of a fire, the fire alarm bell will sound continuous alarm to remind people escape from the fire. The fire alarm can work as a independent bell supplied by main power.
*Size:dia.150mm(6 inch)
*Operating voltage: 2 kinds of voltage optional as below:
For connecting to 220V AC main power, it is a magnetic style fire alarm bell and can work as a bell independently.
For 24V DC voltage,it is a motorised style fire alarm bell which connects with fire alarm system.
We should make sure which voltage and application we need before ordering,because internal construction of fire alarm bell is different.
* Operating current:
≤100mA for magnetic fire alarm bell using 220V AC voltage
≤50mA for motorised fire alarm bell using 24V DC voltage
*Sound level: >95dB
Fire alarm bell 8” size for fire alarm system LX-907-8''A...
This fire alarm bell can be connected with main controller.When the main controller receives signal of a fire, the fire alarm bell will sound continuous alarm to remind people escape from the fire. The fire alarm can work as a stand-alone bell connecting to AC power. It is in 8 inch middle size with minimum decibel up to 97db/1m.Because of its powerful alarm function, the fire alarm ring is suitable for installation at home, school,hotel,office,restaurant,etc.
*Size:dia.200mm(8 inch)
*Operating voltage: 2 kinds of voltage optional as below:
For connecting to 220V AC main power, it is a magnetic style fire alarm bell and can work as a bell independently.
For 24V DC voltage,it is a motorised style fire alarm bell which connects with fire alarm system.
We should make sure which voltage and application we need before ordering,because internal construction of fire alarm bell is different.
* Operating current:
≤100mA for magnetic fire alarm bell using 220V AC voltage
≤50mA for motorised fire alarm bell using 24V DC voltage
*Sound level: >97dB
Conventional 6 inch size fire alarm bell LX-904-6''
This fire alarm bell is connected with main controller.When the main controller receives signal of a fire, the fire alarm bell will sound continuous alarm to remind people escape from the fire.
*Size:dia.152mm(6 inch)
*Rated Voltage:24VDC
* Operating current should not be more than 23mA
*Sound level: >90dB
* Working temperature: -10℃ to+50℃
*Working humidity: ≤95%RH
The fire bell is loud and has powerful alarm function,which is suitable for installation at home, school,hotel,office,restaurant,etc.
The metal shell with coating is waterproof and wear resistance.It can be used for long time.
Conventional 8 inch size fire alarm ring LX-904-8''
This is a motorised fire alarm bell which is connected with main controller.When the main controller receives signal of a fire, the fire alarm bell will sound continuous alarm to remind people escape from the fire.It is in 8 inch middle size with minimum decibel up to 90db/1m.Because of its powerful alarm function, the fire alarm ring is suitable for installation at home, school,hotel,office,restaurant,etc.
The metal shell with coating is waterproof and wear resistance.It can be used for long time.
*Size:dia.203mm(8 inch)
*Rated Voltage:24V DC+/-5%
* Operating current should not be more than 23mA
*Sound level: >90dB
* Working temperature: -10℃ to+50℃
*Working humidity: ≤95%RH
Magnetic fire alarm bell for fire alarm system LX-906
This bell is connected with fire alarm system.When the fire alarm control panel receives signal of a fire, the fire alarm bell will sound continuous alarm to remind people escape from the fire.
*Size:dia.152mm(6 inch)
*Rated Voltage:24VDC+/-5%
* Operating current should not be more than 23mA
*Sound level: >90dB
*Working humidity: ≤95%RH
The iron shell of fire bell is hard and not sasy to deform.With coating on the shell,it is waterproof and can be used for long time.The sound level is higher than 90db,which is suitable for installation at home, school,hotel,office,restaurant,etc.
ufo led lights LX-LF(200/250/300/350)
UFO LED LIGHT BULB
*Modern UFO design with durable aluminum housing,
good heat dissipation and ensures lifespan with meanwell power supply.
*LED light source, PC frame to form lighting and shadow, beautiful lighting effect, non flicker prevents eyes fatigue and provides a comfortable,stress-free atmosphere,ideal for lighting in living room,restaurant,coffee bar,supermarket,etc.
*Easy installation,just plug and play
*More energy-saving and environmentally friendly
Regular white box packing, customized color box is available if customers have special demand
Hot selling independent smoke detector LX-221
This smoke detector adopts photoelectric detector.Photoelectric technology is more sensitive than ionization technology at detecting large particles.Fire is dangerous. We need to install at least one in our bedroom.Stairway is very important for people to rush out when fire occurs.So there must install smoke detectors.Install the smoke detector in the middle of ceiling,because smog and heat always lift up to the top of room.
*Power supplied by 9V DC battery
*Static current:20uA
*Alarm current:10mA
*Alarm sonority: ≥85db
*Working temperature:-10℃--+45℃
*Working humidity<95%RH
*Photoelectric Sensor,LED indicator
*Regular packing is each smoke detector is packed into a neutral white box,100pcs/master carton.
*Testing the smoke alarm: Test each smoke alarm to be sure it is installed correctly and operating properly.Test all smoke alarms weekly by doing the following:
Firmly depress the push- to- test button for at least 5 seconds.The smoke alarm will sound 3 beeps followed by a 2 seconds pause and then repeat.The alarm may sound for up to a few of seconds after releasing the push-to-test button.
Smoke alarm detector with battery LX-222
Model LX-222 smoke alarm adopts photoelectric technology to detect smoke.It is more sensitive to slow smoldering fires and more quick to remind us. Keep our home safe.
This smoke alarm is a stand alone detector supplied by built-in 9V battery.
Red led indicates alarm.Built-in sounder will give sound output of minimum 85db at 3m distance.
The test button accuratly tests all smoke alarm functions.Do not use any other test method. Test smoke alarm weekly to ensure proper operation.
Photoelectric smoke detector with battery LX-223
* Model LX-223 is a stand alone smoke detector supplied by a 9V battery.
*Photoelectric sensor,high sensitivity
*Red led indicate alarm
*The smoke detector is power saving.Static current is less than 20uA.Alarm current is 10mA.But alarm sonority is higher than 85db at 3meters distance.
*Test: It is important to test the detector weekly to make sure it is working properly.Firmly press and hold the test button at least 5 seconds,the smoke alarm will sound 3 short beeps followed by a 2-second pause and then repeats.The alarm may sound up to a few seconds after releasing the button.