Inquiry
Form loading...
Products Categories
Featured Products
220V-240V AC exit sign emergency lights LX-709AT220V-240V AC exit sign emergency lights LX-709AT
01

220V-240V AC exit sign emergency lights LX-709AT

2021-04-30

Indoor use emergency exit sign light

 

*Input Voltage:AC220-240V 50/60HZ

*Rated Power:3W

*14PCS SMD2835 LEDs inside housing with white color light

 

Advantage: this exit emergency lighting has SELF-DIAGNOSTIC function, details as below:

As soon as AC power is supplied to emergency exit sign light ,the unit will automatically initiate a self-diagnostic test.

Verifies battery failure (disconnection,shorted,voltage drops below than acceptable value), charger board failure, lamps failure and transformer failure at every 5 seconds.Manufacturer  pre-sets all functions-Do not need field adjustment.

 

*Dual color LED lamp indicator shows the following status:

⑴ Green color         ON / Ready

               Blinking: Testing

⑵ Red color (Service Alert),Service Alert LED Code (Red color LED lamp indicator)

 

One blink ON/pause (4 seconds ) Battery is not connected
●● Two blink ON/pause (4 seconds ) battery voltage is too low(<4.2V)
●●● Three blink ON/pause(4 seconds ) Charger board fault
●●●● Four blink ON/pause(4 seconds ) Transformer fault
●●●●●●● Seven blink ON/pause(4 seconds ) EXIT LED strip fault

 *Extra test button, press for manual test

*Built-in NI-MH rechargeable battery provides at least 3hours backup power in the event of a power outage, 4.8V 600MAH, 24 hours charging time with battery overcharge and discharge protection

 

*Ceiling mounting,back mounting and side mounting availabe

 

view detail
Rechargeable exit sign emergency lights LX-740GATRechargeable exit sign emergency lights LX-740GAT
01

Rechargeable exit sign emergency lights LX-740GAT

2021-04-30

LED Emergency exit sign light

*Input Voltage:AC220-240V 50/60HZ

*Rated Power:3W

*Aluminum alloy shell with PMMA panel,11 kinds of panel pictograms optional:EXIT,running man,running man with right arrow,running man with up arrow,running man with down arrow,EXIT with running man and right arrow,EXIT with running man and up arrow, EXIT with running man and down arrow,EXIT in english and abric with running man and right arrow,EXIT in english and abric with running man and up arrow,EXIT in english and abric with running man and down arrow

 

*12PCS F5 LEDs inside shell with white color light

The biggest advantage is that this exit emergency lighting has SELF-DIAGNOSTIC function, details as below:

As soon as AC power is supplied to emergency exit sign light ,the unit will automatically initiate a self-diagnostic test.

Verifies battery failure (disconnection,shorted,voltage drops below than acceptable value), charger board failure, lamps failure and transformer failure at every 5 seconds.Manufacturer  pre-sets all functions-Do not need field adjustment.

 

*Extra test button, press for manual test

*Built-in NI-MH rechargeable battery provides at least 3hours backup power in the event of a power outage, 4.8V 600MAH, 24 hours charging time with battery overcharge and discharge protection

 

*There are 3 kinds of installation method:

Ceiling mounting,back mounting, side mounting

view detail
CE listed emergency exit lighting with Self-diagnositc  f...CE listed emergency exit lighting with Self-diagnositc  f...
01

CE listed emergency exit lighting with Self-diagnositc f...

2021-04-30

*Input Voltage:AC220-240V 50/60HZ

*Rated Power:3W

*14PCS SMD2835 LEDs inside housing with white color light

 

Advantage: this exit emergency lighting has SELF-DIAGNOSTIC function, details as below:

As soon as AC power is supplied to emergency exit sign light ,the unit will automatically initiate a self-diagnostic test.

Verifies battery failure (disconnection,shorted,voltage drops below than acceptable value), charger board failure, lamps failure and transformer failure at every 5 seconds.Manufacturer  pre-sets all functions-Do not need field adjustment.

 

*Dual color LED lamp indicator shows the following status:

⑴ Green color         ON / Ready

               Blinking: Testing

⑵ Red color (Service Alert),Service Alert LED Code (Red color LED lamp indicator)

One blink ON/pause (4 seconds ) Battery is not connected
●● Two blink ON/pause (4 seconds ) battery voltage istoolow(<4.2V)
●●● Three blink ON/pause(4 seconds ) Charger board fault
●●●● Four blink ON/pause(4 seconds ) Transformer fault
●●●●●●● Seven blink ON/pause(4 seconds ) EXIT LED strip fault

 

*Extra test button, press for manual test

 

*Built-in NI-MH rechargeable battery provides min. 3hours backup power in the event of a power outage, 4.8V 600MAH, 24 hours charging time after 3 hours discharge, battery overcharge and discharge protection

view detail
Exit sign emergency lights with SELF-DIAGNOSTIC function ...Exit sign emergency lights with SELF-DIAGNOSTIC function ...
01

Exit sign emergency lights with SELF-DIAGNOSTIC function ...

2021-07-09

*Input Voltage:AC220-240V 50/60HZ

*Rated Power:3W

*14PCS SMD2835 LEDs inside housing with white color light

*Extra test button, press for manual test

*4 kinds of graphic optional:running man,running man with right arrow,running man with down arrow,running man with left arrow

 

Advantage: this exit emergency lighting has SELF-DIAGNOSTIC function, details as below:

As soon as AC power is supplied to emergency exit sign light ,the unit will automatically initiate a self-diagnostic test.

Verifies battery failure (disconnection,shorted,voltage drops below than acceptable value), charger board failure, lamps failure and transformer failure at every 5 seconds.Manufacturer  pre-sets all functions-Do not need field adjustment.

 

*Built-in NI-MH rechargeable battery provides min. 3hours backup power in the event of a power outage, 4.8V 600MAH, 24 hours charging time after 3 hours discharge, battery overcharge and discharge protection

 

*CE approval

*Wall surface mounting and wall flush mounting available

view detail
Suspensible Exit emergency light with Self-diagnositc  fu...Suspensible Exit emergency light with Self-diagnositc  fu...
01

Suspensible Exit emergency light with Self-diagnositc fu...

2021-04-30

*Input Voltage:AC220-240V 50/60HZ

*Rated Power:3W

*14PCS SMD2835 LEDs inside housing with white color light

*Extra test button, press for manual test

*4 kinds of graphic optional:running man,running man with right arrow,running man with down arrow,running man with left arrow

 

Advantage: this exit emergency lighting has SELF-DIAGNOSTIC function, details as below:

As soon as AC power is supplied to emergency exit sign light ,the unit will automatically initiate a self-diagnostic test.

Verifies battery failure (disconnection,shorted,voltage drops below than acceptable value), charger board failure, lamps failure and transformer failure at every 5 seconds.Manufacturer  pre-sets all functions-Do not need field adjustment.

 

*Dual color LED lamp indicator shows the following status:

⑴ Green color         ON / Ready

               Blinking: Testing

⑵ Red color (Service Alert),Service Alert LED Code (Red color LED lamp indicator)

 

*Built-in NI-MH rechargeable battery provides min. 3hours backup power in the event of a power outage, 4.8V 600MAH, 24 hours charging time after 3 hours discharge, battery overcharge and discharge protection

 

*CE approval

view detail
CE listed rechargeable exit sign light LX-701CE listed rechargeable exit sign light LX-701
01

CE listed rechargeable exit sign light LX-701

2021-04-30

 This is a maintained exit sign light with emergency function.

*Input voltage:AC220V-240V 50/60HZ

*AC Power:2W

*8PCS LEDs inside housing

 *Aluminum housing, clear organic glass plate with printing of exit signs,double face configuration,total 14 kinds of pictograms optional:

 Running man with right arrow(same direction on double sides), running man with right arrow(different direction on double sides),running man,running man with up arrow,running man with down arrow,EXIT with running man and right arrow(same direction on double sides), EXIT in english and abric with running man and right arrow(same direction on double sides),EXIT in english and abric with running man and down arrow,EXIT in english and abric with running man and up arrow, EXIT in english and abric with running man and right arrow(different direction on double sides), EXIT with running man and right arrow(different direction on double sides),EXIT with running man and up arrow,EXIT with running man and down arrow,EXIT

 

*Built-in nickel cadmium battery provides at least 3hours backup power in the event of a power outage:3.6V 600mAh, it is rechargeable battery, maximum 24 hours  for full recharge,with battery overcharge and discharge protection

 

*Fault led indicator and test button:There are red and yellow led indicator lights to show us normal charging state and fault state.               

*TUV CE approval,the exit sign emergency light can be used in Europe,Asia and middle east market.

 

*Installation method: Install two hooks in the ceiling;hang one end of the two link chains on the exit light respectively;Then hang the other end of the two link chains over the hooks  in the ceiling respectively*Suitable for both commercial and residential areas

view detail
CE listed suspending type emergency exit  lights LX-703CE listed suspending type emergency exit  lights LX-703
01

CE listed suspending type emergency exit lights LX-703

2021-04-30

This 2W emergency exit light is a robust, cost effective lighting solution for interior applications. The exit sign light is easy to mount and suitable for mounting on emergency escape routes as defined.

*Input voltage:AC220V-240V 50/60HZ

*AC Power:2W

*8PCS LEDs inside housing

*Aluminum housing, clear organic glass plate with printing of exit signs,double face configuration,total 14 kinds of pictograms optional:

 

Running man with right arrow(same direction on double sides), running man with right arrow(different direction on double sides),running man,running man with up arrow,running man with down arrow,EXIT with running man and right arrow(same direction on double sides), EXIT in english and abric with running man and right arrow(same direction on double sides),EXIT in english and abric with running man and down arrow,EXIT in english and abric with running man and up arrow, EXIT in english and abric with running man and right arrow(different direction on double sides), EXIT with running man and right arrow(different direction on double sides),EXIT with running man and up arrow,EXIT with running man and down arrow,EXIT

 

*Built-in nickel cadmium battery provides at least 3hours backup power in the event of a power outage:3.6V 600mAh, it is rechargeable battery, maximum 24 hours  for full recharge,with battery overcharge and discharge protection

 

*Fault led indicator and test button:There are red and yellow led indicator lights to show us normal charging state and fault state.               

*TUV CE approval,the exit sign emergency light can be used in Europe,Asia and middle east market.

view detail
Led exit sign emergency lights ceiling flush mounted LX-7...Led exit sign emergency lights ceiling flush mounted LX-7...
01

Led exit sign emergency lights ceiling flush mounted LX-7...

2021-05-26

Indoor use emergency exit sign light

*Input Voltage:AC220-240V 50/60HZ

*Rated Power:3W

*Fire retardant ABS shell,PMMA panel with double face running man image,different pictograms optional:EXIT,running man,running man with right arrow,running man with up arrow,running man with down arrow,EXIT with running man and right arrow,EXIT with running man and up arrow, EXIT with running man and down arrow,EXIT in english and abric with running man and right arrow,EXIT in english and abric with running man and up arrow,EXIT in english and abric with running man and down arrow

 

*14PCS SMD2835 LEDs inside shell with white color light

*Extra test button, press for manual test

*Built-in NI-MH rechargeable battery provides at least 3hours backup power in the event of a power outage, 4.8V 600MAH, 24 hours charging time with battery overcharge and discharge protection

 Feature 1: this exit emergency lighting has SELF-DIAGNOSTIC function, details as below:

As soon as AC power is supplied to emergency exit sign light ,the unit will automatically initiate a self-diagnostic test.

Verifies battery failure (disconnection,shorted,voltage drops below than acceptable value), charger board failure, lamps failure and transformer failure at every 5 seconds.Manufacturer  pre-sets all functions-Do not need field adjustment.

 

Feature 2:The shell structure of the exit light is suitable for ceiling flush mounting. That looks good and space saving.

view detail
Fire alarm control panel LX-801-4Fire alarm control panel LX-801-4
01

Fire alarm control panel LX-801-4

2021-04-28

CONVENTIONAL FIRE ALARM PANEL,4 ZONES

This control panel can be connected with a number of conventional devices, such as conventional smoke detectors,heat detectors, manual call points,fire alarms and fire alarm bells.All these devices work together as a system  to detect and warn people  

 through visual and audio appliances when smoke, fire, carbon monoxide or other emergencies are present.Through the panel,these alarms may be activated

 automatically from smoke detectors, and heat detectors or may also be activated via manual fire alarm activation devices such as manual call points. The panel buzzer will sound if any fault occur (detector fault,zone wiring fault,AC mains failure,

battery fault or disconnected,alarm output wiring fault.

 

*Input voltage:240VAC+/-10% 50/60HZ

*Built-in lead-acid battery: 24VDC,rechargeable, work as backup power supply

*Charging voltage protection: 1.6Ah glass fuse

*Sounder output: 24V nominal EOL 10K resistor

* Auxiliary contacts: 30VDC, 1A max. NC/NO

*Main supply protection: glass fuse

*Sounder protection: 2 x 500mA glass fuse

*Reverse battery protection: charger glass fuse

*Zone EOL: 5.6K resistor

*Color: ivory,blue,black

*Zoned visual red alarm and yellow trouble indicators

*Continuous signal during alarm

*Low / no power and battery detection

*Automatic loading and testing of battery

*Battery lead reversal protection

*Evacuate (alarm resound)

*LED test

3145852

view detail
Fire alarm control panel 12 zones LX-801-12Fire alarm control panel 12 zones LX-801-12
01

Fire alarm control panel 12 zones LX-801-12

2021-04-28

This control panel can be connected with a number of conventional devices, such as conventional smoke detectors,heat detectors, manual call points,fire alarms and fire alarm bells.All these devices work together as a system  to detect and warn people  

 through visual and audio appliances when smoke, fire, carbon monoxide or other emergencies are present.Through the panel,these alarms may be activated

 automatically from smoke detectors, and heat detectors or may also be activated via manual fire alarm activation devices such as manual call points. The panel buzzer will sound if any fault occur (detector fault,zone wiring fault,AC mains failure,

battery fault or disconnected,alarm output wiring fault.

 

*Input voltage:240VAC+/-10% 50/60HZ

*Built-in lead-acid battery: 24VDC,rechargeable, work as backup power supply

*Charging voltage protection: 1.6Ah glass fuse

*Sounder output: 24V nominal EOL 10K resistor

* Auxiliary contacts: 30VDC, 1A max. NC/NO

*Main supply protection: glass fuse

*Sounder protection: 2 x 500mA glass fuse

*Reverse battery protection: charger glass fuse

*Zone EOL: 5.6K resistor

*Color: ivory,blue,black

*Zoned visual red alarm and yellow trouble indicators

*Continuous signal during alarm

*Low / no power and battery detection

*Automatic loading and testing of battery

*Battery lead reversal protection

*Evacuate (alarm resound)

*LED test

view detail
20 Zones Fire alarm control panel with backup battery LX-...20 Zones Fire alarm control panel with backup battery LX-...
01

20 Zones Fire alarm control panel with backup battery LX-...

2021-04-28

This control panelcan be connected with a number of conventional devices, such as conventional smoke detectors,heat detectors, manual call points,fire alarms and fire alarm bells.All these devices work together as a system  to detect and warn people  

 through visual and audio appliances when smoke, fire, carbon monoxide or other emergencies are present.Through the panel,these alarms may be activated

 automatically from smoke detectors, and heat detectors or may also be activated via manual fire alarm activation devices such as manual call points. The panel buzzer will sound if any fault occur (detector fault,zone wiring fault,AC mains failure,

battery fault or disconnected,alarm output wiring fault.

 

*Input voltage:240VAC+/-10% 50/60HZ

*Built-in lead-acid battery: 24VDC,rechargeable, work as backup power supply

*Charging voltage protection: 1.6Ah glass fuse

*Sounder output: 24V nominal EOL 10K resistor

* Auxiliary contacts: 30VDC, 1A max. NC/NO

*Main supply protection: glass fuse

*Sounder protection: 2 x 500mA glass fuse

*Reverse battery protection: charger glass fuse

*Zone EOL: 5.6K resistor

*Color: ivory,blue,black

*Zoned visual red alarm and yellow trouble indicators

*Continuous signal during alarm

*Low / no power and battery detection

*Automatic loading and testing of battery

*Battery lead reversal protection

*Evacuate (alarm resound)

*LED test

view detail